ABCB Housing Provisions 2022
Part 13.4 Building sealing
7 clauses · Open on NCC Online ↗
- 13.4.1 Application of Part 13.4 NSW NTThis Part applies to— a Class 1 building; and a Class 10a building with a conditioned space. (2) The provisions of (1) do not apply to the…
- 13.4.2 Chimneys and flues NTThe chimney or flue of an open solid-fuel burning appliance must be provided with a damper or flap that can be closed to seal the chimney or flue.
- 13.4.3 Roof lights NTA roof light must be sealed, or capable of being sealed, when serving— a conditioned space; or a habitable room in climate zones 4, 5, 6, 7 and 8.…
- 13.4.4 External windows and doors NTAn external door, internal door between a Class 1 building and an unconditioned Class 10a building, openable window and other such opening must be…
- 13.4.5 Exhaust fans NTAn exhaust fan must be fitted with a sealing device such as a self-closing damper, filter or the like when serving— a conditioned space; or a…
- 13.4.6 Construction of ceilings, walls and floors NTCeilings, walls, floors and any opening such as a window frame, door frame, roof light frame or the like must be constructed to minimise air leakage…
- 13.4.7 Evaporative coolers NTAn evaporative cooler must be fitted with a self-closing damper or the like when serving— a heated space; or a habitable room in climate zones 4, 5,…