13.4.6 Construction of ceilings, walls and floors
Part 13.4 Building sealing · NCC 2019: 3.12.3.5
Varied in NT. Check the variation for your state.
(1) Ceilings, walls, floors and any opening such as a window frame, door frame, roof light frame or the like must be constructed to minimise air leakage in accordance with (2) when forming part of the external fabric of—
a conditioned space; or
a habitable room in climate zones 4, 5, 6, 7 and 8.
(2) Construction required by (1) must be—
enclosed by internal lining systems that are close fitting at ceiling, wall and floor junctions; or
sealed at junctions and penetrations with—
close-fitting architrave, skirting or cornice; or
expanding foam, rubber compressive strip, caulking or the like.
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 13.4.6.