13.7.8 Swimming pool heating and pumping
Part 13.7 Services · NCC 2019: 3.12.5.7
Varied in NSW. Check the variation for your state.
(1) Heating for a swimming pool must be by—
a solar heater not boosted by electric resistance heating; or
a heater using reclaimed energy; or
a gas heater; or
a heat pump; or
a combination of (a) to (d).
(2) Where some or all of the heating required by (1) is by a gas heater or a heat pump, the swimming pool must have—
a cover with a minimum R-Value of 0.05, unless located in a conditioned space; and
a time switch to control the operation of the heater.
(3) A time switch must be provided to control the operation of a circulation pump for a swimming pool.
(4) For the purposes of 13.7.8, a swimming pool does not include a spa pool.
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 13.7.8.