- 13.7.1 Application of Part 13.7 NSW NTThis Part applies to— a Class 1 building; and a Class 10a building; and a Class 10b swimming pool associated with a Class 1 or 10a building. (2)…
- 13.7.2 Insulation of services NTThermal insulation for central heating water piping and heating and cooling ductwork must— be protected against the effects of weather and sunlight;…
- 13.7.3 Central heating water piping NTCentral heating water piping that is not within a conditioned space must be thermally insulated to achieve the minimum material R-Values as set out…
- 13.7.4 Heating and cooling ductwork NTHeating and cooling ductwork and fittings must— achieve the material R-Value in (4); and be sealed against air loss— by closing all openings in the…
- 13.7.5 Electric resistance space heating NSW NTAn electric resistance space heating system that serves more than one room must have— separate isolating switches for each room; and a separate…
- 13.7.6 Artificial lighting NSWThe lamp power density or illumination power density of artificial lighting, excluding heaters that emit light, must not exceed the allowance of— 5…
- 13.7.7 Water heater in a heated water supply system NSWA water heater in a heated water supply system must be designed and installed in accordance with Part B2 of NCC Volume Three — Plumbing Code of…
- 13.7.8 Swimming pool heating and pumping NSWHeating for a swimming pool must be by— a solar heater not boosted by electric resistance heating; or a heater using reclaimed energy; or a gas…
- 13.7.9 Spa pool heating and pumping NSWHeating for a spa pool that shares a water recirculation system with a swimming pool must be by— a solar heater; or a heater using reclaimed energy;…