Housing Provisions clause · ABCB Housing Provisions 2022

13.7.9 Spa pool heating and pumping

Part 13.7 Services · NCC 2019: 3.12.5.8

Open 13.7.9 on NCC Online ↗
Varied in NSW. Check the variation for your state.

(1) Heating for a spa pool that shares a water recirculation system with a swimming pool must be by—

a solar heater; or

a heater using reclaimed energy; or

a gas heater; or

a heat pump; or

a combination of (a) to (d).

(2) Where some or all of the heating required by (1) is by a gas heater or a heat pump, the spa pool must have—

a cover; and

a push button and a time switch to control the operation of the heater.

(3) A time switch must be provided to control the operation of a circulation pump for a spa pool having a capacity of 680 L or more.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 13.7.9.

State and territory variations all clauses side by side →

Defined terms used