3.3.2 Drainage requirements
Part 3.3 Drainage · NCC 2019: 3.1.3.2
Drainage systems must be installed as follows:
Areas adjoining and under buildings — surface water drainage in accordance with 3.3.3; and
Where site conditions exist that create a need for subsoil water to be diverted away from footings, basements, retaining walls etc — sub-soil drainage in accordance with 3.3.4; and
Where underground drainage from roof areas is required or permitted — underground stormwater drainage in accordance with 3.3.5; and
Excavation for drains adjacent to existing footings must be within the area described in Figure 3.3.2 as being safe for excavation.
Figure 3.3.2 Excavation for drains adjacent to footings
Figure Notes
Any excavation below the area defined as being safe for excavation will need additional protection measures to be determined by appropriately qualified persons.
Slope ratio H:L is determined using Table 3.2.1.
Clauses referred to
- 3.3.3 Surface water drainage
- 3.3.4 Subsoil drainage
- 3.3.5 Stormwater drainage
- 3.2.1 Un-retained bulk earthworks – site cut and fill