Housing Provisions clause · ABCB Housing Provisions 2022

4.2.11 Steel reinforcement

Part 4.2 Footings, slabs and associated elements · NCC 2019: 3.2.3.2

Open 4.2.11 on NCC Online ↗

(1) Materials used for reinforcing steel must comply with AS 2870 and be—

welded wire reinforcing fabric; or

trench mesh; or

steel reinforcing bars.

(2) Steel reinforcing bars may be substituted for trench mesh in accordance with Table 4.2.11a.

(3) Minimum laps for reinforcement as shown in Table 4.2.11b and Figure 4.2.11a must be provided where reinforcing is used.

(4) Any slab in H1D4 with a re-entrant corner must have—

two strips of 3-L8TM; or

one strip of 3-L11TM; or

3-N12 bars,

not less than 2 m in length and placed at an angle of 45° across the corner such that the centre of the 2 m length is at the location of the internal angle of the slab in accordance with Figure 4.2.11b.

(5) Footings and slabs-on-ground must have concrete cover between the outermost edge of the reinforcement (including ligatures, tie wire etc.) and the surface of the concrete of not less than—

40 mm to unprotected ground; and

30 mm to a membrane in contact with the ground; and

20 mm to an internal surface; and

40 mm to external exposure.

(6) Reinforcement must be free of loose rust, mud, paints and oils.

(7) Reinforcement must be placed as follows:

All reinforcement must be firmly fixed in place to prevent it moving during concreting operations.

Reinforcement must be supported off the ground or the forms by bar chairs made from wire, concrete or plastic.

When using wire chairs, the minimum concrete cover (see (5)) to the uncoated portion of the chair must be obtained.

Wire chairs on soft ground or plastic membrane must be placed on flat bases.

Bar chairs must be spaced at not more than 800 mm centres for steel fabric.

Table 4.2.11a Alternative mesh/reinforcing bar sizes

Trench mesh (TM)

Area — mm2

Reinforcing bar alternative

Trench mesh alternative

2-L8TM

91

2-N10 or 1-N12

Not applicable

3-L8TM

136

2-N10 or 2-N12

Not applicable

4-L8TM

182

2-N12

2-L11TM

5-L8TM

227

2-N12

3-L11TM

2-L11TM

180

1-N16 or 2-N12

2x2-L8TM

3-L11TM

270

3-N12

2x3-L8TM

4-L11TM

360

2-N16

2x4-L8TM

2-L12TM

222

2-N12

3-L11TM

3-L12TM

333

3-N12

4-L11TM

4-L12TM

444

4-N12

5-L11TM

Table Notes

Where necessary, 2 layers of mesh may be used.

L11TM and L12TM may be replaced by RL1118 and RL1218 mesh respectively.

L11TM may be replaced by two layers of L8TM.

Table 4.2.11b Minimum lap for reinforcement

Reinforcement

Minimum splice

Minimum lap at “T” intersections

Minimum lap at “L” intersections

Steel reinforcing bars ≤12 mm diameter

500 mm

Full width across the junction

One outer bar must be bent and continue 500 mm (min) around corner

Steel reinforcing bars >12 mm to ≤16 mm diameter

700 mm

Full width across the junction

One outer bar must be bent and continue 500 mm (min) around corner

Trench mesh

500 mm

Full width across the junction

Full width across the junction

Square and rectangular mesh

The two outermost transverse wires of one sheet must overlap the two outermost transverse wires of the other

Not applicable

Not applicable

Figure 4.2.11a Splice, L and T intersections

Figure 4.2.11b Reinforcing for re-entrant corners

Tables

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 4.2.11.

Defined terms used