9.5.3 Location – Class 1b buildings
Part 9.5 Smoke alarms and evacuation lighting · NCC 2019: 3.7.5.4
In a Class 1b building, smoke alarms must be located in—
every bedroom; and
every corridor or hallway associated with a bedroom, or if there is no corridor or hallway, in an area between the bedrooms and the remainder of the building; and
each other storey.
Notes
Figure 9.5.3 illustrates requirements of this provision.
Figure 9.5.3 Class 1b building where multiple bedrooms are served by a hallway
Figure Notes
In this diagram—
the location of each smoke alarm is indicated by a black dot; and
the location of a smoke alarm with evacuation lighting is indicated by a black dot within a square; and
the area served by evacuation lighting is indicated by grey shading.
Smoke alarms are required to be interconnected by 9.4.1(d).
Lighting in the grey shaded area is to be activated by a smoke alarm if using 9.5.5(b)(ii).