9.5.3 Location – Class 1b buildings

Part 9.5 Smoke alarms and evacuation lighting · NCC 2019: 3.7.5.4

Open 9.5.3 on NCC Online ↗

In a Class 1b building, smoke alarms must be located in—

every bedroom; and

every corridor or hallway associated with a bedroom, or if there is no corridor or hallway, in an area between the bedrooms and the remainder of the building; and

each other storey.

Notes

Figure 9.5.3 illustrates requirements of this provision.

Figure 9.5.3 Class 1b building where multiple bedrooms are served by a hallway

Figure Notes

In this diagram—

the location of each smoke alarm is indicated by a black dot; and

the location of a smoke alarm with evacuation lighting is indicated by a black dot within a square; and

the area served by evacuation lighting is indicated by grey shading.

Smoke alarms are required to be interconnected by 9.4.1(d).

Lighting in the grey shaded area is to be activated by a smoke alarm if using 9.5.5(b)(ii).

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 9.5.3.