NT 10.7.3 Soil and waste pipes
NT Part 10.7 Sound insulation · varies 10.7.3 Construction of sound insulated walls
If a soil or waste pipe passes through a separating wall—
a door or panel providing access to the pipe must not open into any habitable room, other than a kitchen; and
an access door or panel in any other part must be firmly fixed so as to overlap the frame or rebate of the frame by not less than 10 mm, be fitted with a sealing gasket along all edges and constructed of—
wood, plasterboard or blockboard not less than 38 mm thick; or
compressed fibre reinforced cement sheeting not less than 9 mm thick; or
other suitable material with a mass per unit area not less than 24.4. kg/m2.