ABCB Housing Provisions 2022
Northern Territory variations
32 NT variations to ABCB Housing Provisions 2022: clauses replaced, added or deleted in Northern Territory. Search with NT variations.
- NT 3.4.1 Requirements for termite management systemsDelete subclause 3.4.1(2) and insert NT 3.4.1(2) as follows: (2) For the purposes of (1), a primary building element consisting entirely of, or a…
- NT 3.4.2 Termite management systemsDelete clause 3.4.2 and insert NT 3.4.2 as follows: Where a termite management system is required it must— be selected appropriate to Table 3.4.2;…
- NT 10.7.1 Sound insulation requirementsA separating wall between two or more Class 1 buildings must— achieve the weighted sound reduction index (RW) and impact sound resistance required…
- NT 10.7.2 General installation requirements for wallsTo achieve an appropriate RW and impact sound resistance, walls must— be installed in accordance with the appropriate requirements contained in (2)…
- NT 10.7.3 Soil and waste pipesIf a soil or waste pipe passes through a separating wall— a door or panel providing access to the pipe must not open into any habitable room, other…
- NT 13.1.1 ScopeThis Section sets out the following Deemed-to-Satisfy Provisions for energy efficiency: Building fabric (see NT Part 13.2). External glazing (see NT…
- NT 13.1.2 ApplicationThe application of this Section is subject to the following: The Governing Requirements of NCC Volume Two. The Northern Territory variations,…
- NT 13.2.1 Application of Part 13.2The provisions of NT 13.2.2 to NT 13.2.6 apply to— a Class 1 building; and a Class 10a building with a conditioned space. (2) The provisions of NT…
- NT 13.2.2 Building fabric thermal insulationWhere required, insulation must comply with AS/NZS 4859.1 and be installed so that it— abuts or overlaps adjoining insulation other than at…
- NT 13.2.3 RoofsA roof must achieve the Total R-Value of 2.7 for the downwards direction of heat flow in climate zone 1 and downwards and upwards in climate zone 3.…
- NT 13.2.4 Roof lightsRoof lights serving a habitable room or an interconnecting space such as a corridor, hallway, stairway or the like— if the total area of the roof…
- NT 13.2.5 External wallsEach part of an external wall must satisfy (2) or (3), except for— an external wall facing the south orientation sector, as described in NT Figure…
- NT 13.2.6 Attached Class 10a buildingsA Class 10a building attached to a Class 1 building must— have an external fabric that achieves the required level of thermal performance for a…
- NT 13.3.1 Application of Part 13.3This Part applies to— a Class 1 building; and a Class 10a building with a conditioned space.
- NT 13.3.2 External glazingCompliance with this part is demonstrated with a “passed” result produced with the ABCB Glazing calculator certificate for the glazing in the…
- NT 13.3.3 ShadingWhere shading is required to comply with NT 13.3.2, it must— be provided by an external permanent projection, such as a verandah, balcony, fixed…
- NT 13.4.1 Application of Part 13.4This Part applies to— a Class 1 building; and a Class 10a building with a conditioned space. Applications This Part does not apply to: A building…
- NT 13.4.2 Chimneys and fluesThe chimney or flue of an open solid-fuel burning appliance must be provided with a damper or flap that can be closed to seal the chimney or flue.
- NT 13.4.3 Roof lightsA roof light must be sealed, or capable of being sealed, when serving a conditioned space. (2) A roof light required by (1) must be constructed…
- NT 13.4.4 External windows and doorsA seal to restrict air infiltration must be fitted to each edge of an external door, openable window and other such opening when serving a…
- NT 13.4.5 Exhaust fansAn exhaust fan must be fitted with a sealing device such as a self-closing damper, filter or the like when serving a conditioned space.
- NT 13.4.6 Construction of ceilings, walls and floorsCeilings, walls, floors and any opening such as a window frame, door frame, roof light frame or the like must be constructed to minimise air leakage…
- NT 13.4.7 Evaporative coolersAn evaporative cooler must be fitted with a self-closing damper or the like when serving a heated space.
- NT 13.5.1 Application of Part 13.5This Part applies to a habitable room in a Class 1 building.
- NT 13.5.2 Air movementAir movement must be provided to habitable rooms in accordance with Table NT 13.5.2. (2) Air movement required by (1) may be provided through an…
- NT 13.5.3 Ventilation openingsThe total ventilation opening area required by Table NT 13.5.2 to a habitable room must— be connected by a breeze path complying with (b) to another…
- NT 13.7.1 Application of Part 13.7This Part applies to— a Class 1 building; and a Class 10a building.
- NT 13.7.2 Insulation of servicesThermal insulation for central heating water piping and heating and cooling ductwork must be— protected against the effects of weather and sunlight;…
- NT 13.7.3 Central heating water pipingCentral heating water piping that is not within a conditioned space must be thermally insulated to achieve the minimum Total R-Value of 0.6. (2)…
- NT 13.7.4 Heating and cooling ductworkHeating and cooling ductwork and fittings must— achieve the minimum Total R-Value in accordance with NT Table 13.7.4; and use thermal insulation…
- NT 13.7.5 Water heater in a heated water supply systemA water heater in a heated water supply system must be designed and installed in accordance with Part B2 of NCC Volume Three – Plumbing Code of…
- NT Part 13.6 Whole-of-home energy usageThis Part is deleted from the BCA in Northern Territory.