Northern Territory variation · ABCB Housing Provisions 2025

NT 10.7.3 Soil and waste pipes

NT Part 10.7 Sound insulation · varies 10.7.3 Construction of sound insulated walls

Open on NCC Online ↗

Insert NT clause 10.7.3 in clause 10.7.3 as follows:

If a soil or waste pipe passes through a separating wall—

a door or panel providing access to the pipe must not open into any habitable room, other than a kitchen; and

an access door or panel in any other part must be firmly fixed so as to overlap the frame or rebate of the frame by not less than 10 mm, be fitted with a sealing gasket along all edges and constructed of—

wood, plasterboard or blockboard not less than 38 mm thick; or

compressed fibre reinforced cement sheeting not less than 9 mm thick; or

other suitable material with a mass per unit area not less than 24.4. kg/m2.

Changed since NCC 2022. See ABCB Housing Provisions 2022 NT 10.7.3, or show what changed.

Insert NT clause 10.7.3 in clause 10.7.3 as follows: If a soil or waste pipe passes through a separating … a mass per unit area not less than 24.4. kg/m2.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause