Northern Territory variation · ABCB Housing Provisions 2022

NT 13.2.4 Roof lights

NT Part 13.2 Building fabric · varies 13.2.4 Roof lights

Open on NCC Online ↗

Roof lights serving a habitable room or an interconnecting space such as a corridor, hallway, stairway or the like—

if the total area of the roof lights is more than 1.5% but not more than 10% of the floor area of the room or space, must comply with Table NT 13.2.4; or

if the total area of the roof lights is more than 10% of the floor area of the room or space they serve, may only be used where—

compliance with the natural lighting requirements can only be achieved by a roof light; and

the transparent and translucent elements of the roof lights, imperforate ceiling diffuser, achieve— including any

an SHGC of not more than 0.25; and

a Total U-Value of not more than 1.3; and

The aggregate area of roof lights serving a building must not exceed 3% of the total area of the floor of the storey served.

Insert NT table (13.2.4) 13.2.4 as follows:

NT Table 13.2.4: Roof lights – thermal performance of transparent and translucent elements

Roof light shaft index

Total area of roof lights serving the room or space as a percentage of the floor area of the room or space

Up to 5% of the floor area of the room or space

More than 5% and up to 10%

Less than 0.5

SHGC of not more than 0.5 and a Total U-Value of not more than 5.0

SHGC of not more than 0.25 and a Total U-Value of not more than 2.5

1.0 to 2.5

Total U-Value of not more than 5.0

SHGC of not more than 0.25 and a Total U-Value of not more than 2.5

2.5 and above

Total U-Value of not more than 5.0

SHGC of not more than 0.25 and a Total U-Value of not more than 2.5

Table Notes

The roof light shaft index is determined by measuring the distance from the centre of the shaft at the roof to the centre of the shaft at the ceiling level and dividing it by the average internal dimension of the shaft opening at the ceiling level (or the diameter for a circular shaft) in the same units of measurement.

The total area of roof lights is the combined area for all roof lights serving the room or space.

The area of a roof light is the area of the roof opening that allows light to enter the building.

The thermal performance of an imperforate ceiling diffuser may be included in the Total U-Value of the roof light.

Changed in NCC 2025. See ABCB Housing Provisions 2025 NT 13.2.4, or show what changed.

Insert NT clause 13.2.4 in clause 13.2.4 as follows: Roof lights serving a habitable room or an interconnecting space … be included in the Total U-Value of the roof light.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause

Other states and territories