Northern Territory variation · ABCB Housing Provisions 2022
NT 3.4.1 Requirements for termite management systems
Part 3.4 Termite risk management · varies 3.4.1 Requirements for termite management systems
Delete subclause 3.4.1(2) and insert NT 3.4.1(2) as follows:
(2) For the purposes of (1), a primary building element consisting entirely of, or a combination of, any of the following materials is considered not subject to termite attack:
Steel, aluminium or other metals.
Concrete.
Masonry.
Fibre-reinforced cement.
Timber — naturally termite resistant in accordance with Appendix C of AS 3660.1 in areas where Mastotermes darwiniensis are not prevalent.
Timber — preservative treated in accordance with Appendix D of AS 3660.1.
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 NT 3.4.1.