Northern Territory variation · ABCB Housing Provisions 2025

NT 3.4.1 Requirements for termite management systems

NT Part 3.4 Termite risk management · varies 3.4.1 Requirements for termite management systems

Open on NCC Online ↗

Delete subclause 3.4.1(2) and insert NT 3.4.1(2) as follows:

(2) For the purposes of (1), a primary building element consisting entirely of, or a combination of, any of the following materials is considered not subject to termite attack:

Steel, aluminium or other metals.

Concrete.

Masonry.

Fibre-reinforced cement.

Timber — naturally termite resistant in accordance with Appendix C of AS 3660.1 in areas where Mastotermes darwiniensis are not prevalent.

Timber — preservative treated in accordance with Appendix D of AS 3660.1.

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 NT 3.4.1.