Table 13.2.3u Metal-framed flat, skillion or cathedral roof – thermal bridging mitigation

Part 13.2 Building fabric

Open Table 13.2.3u on NCC Online ↗
Minimum ceiling insulation R-Value from Tables 13.2.3j to 13.2.3rOption 1 – increase insulation between roof frame members to specified minimum R-ValueOption 2 – add a layer of continuous insulation with specified minimum R-Value above or below the roof frame members
1.01.50.13
1.52.50.30
2.03.50.30
2.55.00.40
3.06.00.60
3.5X0.60
4.0X0.60
4.5X0.60
5.0X0.60
5.5X0.60
6.0X0.60

Table Notes

Minimum R-Values are in-situ values. They account for compression of insulation.

X = not permitted.

Table for 13.2.3 Roofs and ceilings

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.2.3u.