Table · ABCB Housing Provisions 2022

Table 13.2.5l Masonry cavity wall – minimum insulation R-Value: climate zone 6

Part 13.2 Building fabric

Open Table 13.2.5l on NCC Online ↗
SAOverhang (mm)Wall height (m)
≤ 2.4> 2.4 to ≤ 2.7> 2.7 to ≤ 3.0> 3.0 to ≤ 3.6
≤ 0.3500.510.621.081.44
> 0 to ≤ 3001.081.081.081.44
> 300 to ≤ 4501.441.081.081.44
> 450 to ≤ 6001.441.441.081.44
> 600 to ≤ 900XX1.44X
> 900 to ≤ 1200XXXX
> 0.35 to ≤ 0.500.510.620.751.08
> 0 to ≤ 3000.750.751.081.44
> 300 to ≤ 4501.081.081.081.44
> 450 to ≤ 6001.441.081.081.44
> 600 to ≤ 900XX1.441.44
> 900 to ≤ 1200XXXX
> 0.5 to ≤ 0.700.250.510.621.08
> 0 to ≤ 3000.620.620.751.08
> 300 to ≤ 4501.080.751.081.08
> 450 to ≤ 6001.441.081.081.08
> 600 to ≤ 900X1.441.441.44
> 900 to ≤ 1200XXX1.44
> 0.7 to ≤ 0.8500.250.510.511.08
> 0 to ≤ 3000.620.510.751.08
> 300 to ≤ 4501.080.620.751.08
> 450 to ≤ 6001.081.081.081.08
> 600 to ≤ 900X1.441.081.44
> 900 to ≤ 1200XX1.441.44

Table Notes

SA = solar absorptance.

R-Values listed are for the labelled, declared R-Value of insulation.

X = not permitted.

This Table shows wall heights for single storey dwellings. For two storey (or more) dwellings, add R0.25 to the R-Values given in this Table, to a maximum R-Value of R1.44.

Table for 13.2.5 External walls

Changed in NCC 2025. See ABCB Housing Provisions 2025 Table 13.2.5l, or show what changed.

SA | Overhang (mm) | Wall height (m) ≤ 2.4 … given in this Table, to a maximum R-Value of R1.44. Where an overhang of > 1200 mm is used, the values for > 900 to ≤ 1200 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 1200 mm.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used