Table · ABCB Housing Provisions 2022

Table 13.2.5m Masonry veneer wall – minimum insulation R-Value: climate zone 7

Part 13.2 Building fabric

Open Table 13.2.5m on NCC Online ↗
SAOverhang (mm)Wall height (m)
≤ 2.4> 2.4 to ≤ 2.7> 2.7 to ≤ 3.0> 3.0 to ≤ 3.6
≤ 0.3501.51.51.52.4
> 0 to ≤ 3002.01.52.02.4
> 300 to ≤ 4502.42.02.02.4
> 450 to ≤ 600X2.42.02.4
> 600 to ≤ 900XXXX
> 900 to ≤ 1200XXXX
> 0.35 to ≤ 0.501.51.51.52.0
> 0 to ≤ 3001.51.52.02.4
> 300 to ≤ 4502.42.02.02.4
> 450 to ≤ 600X2.02.02.4
> 600 to ≤ 900XX2.52.4
> 900 to ≤ 1200XXXX
> 0.5 to ≤ 0.701.51.51.52.0
> 0 to ≤ 3001.51.51.52.0
> 300 to ≤ 4502.01.51.52.0
> 450 to ≤ 6002.52.02.02.0
> 600 to ≤ 900XX2.42.4
> 900 to ≤ 1200XXXX
> 0.7 to ≤ 0.8501.51.51.51.5
> 0 to ≤ 3001.51.51.52.0
> 300 to ≤ 4502.01.51.52.0
> 450 to ≤ 6002.42.02.02.0
> 600 to ≤ 900XX2.42.0
> 900 to ≤ 1200XXX2.4

Table Notes

SA = solar absorptance.

R-Values listed are for the labelled, declared R-Value of insulation.

X = not permitted.

This Table shows wall heights for single storey dwellings. For two storey (or more) dwellings, add R0.5 to the R-Values given in this Table.

Table for 13.2.5 External walls

Changed in NCC 2025. See ABCB Housing Provisions 2025 Table 13.2.5m, or show what changed.

SA | Overhang (mm) | Wall height (m) ≤ 2.4 … dwellings, add R0.5 to the R-Values given in this Table. Where an overhang of > 900 mm is used, the values for > 600 to ≤ 900 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 900 mm.

Removed words are struck through; added words are highlighted. Comparison of the text only.