Table · ABCB Housing Provisions 2022

Table 13.2.5s Concrete block walls with internal lining fixed to a metal frame – thermal bridging mitigation

Part 13.2 Building fabric

Open Table 13.2.5s on NCC Online ↗
Wall insulation R-Values from Tables 13.2.5a to 13.2.5eOption 1 – increase insulation between wall framing to specified minimum R-ValueOption 2 – add a layer of continuous insulation with specified minimum R-Value on the inside or outside of the wall framing
0 or reflectiveNot requiredNot required
0.5 or 1.01.50.13
1.5, 2.0 or 2.5X0.30

Table Notes

X = not permitted.

Minimum R-Values are in-situ values. They account for compression of insulation.

Table for 13.2.5 External walls

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.2.5s.