Table 13.2.5t Lightweight metal-framed walls – thermal bridging mitigation

Part 13.2 Building fabric

Open Table 13.2.5t on NCC Online ↗
Wall insulation R-Value from Tables 13.2.5a to 13.2.5oThermal bridging mitigation
0 or reflectiveNot required
>0 to ≤1.5Either install reflective insulation outside the frame to create a minimum 20 mm reflective airspace between frame and cladding, or increase insulation between frames by R0.5.
>1.5Either install reflective insulation outside the frame to create a minimum 20 mm reflective airspace between frame and cladding, or add a layer of continuous insulation with an R-Value of at least R0.30 on the inside or the outside of the frame.

Table Notes

Minimum R-Values are in-situ values. They account for compression of insulation.

The surface emittance of a reflective surface facing an airspace must be a maximum of 0.1.

Table for 13.2.5 External walls

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.2.5t.