Table · ABCB Housing Provisions 2022

Table 13.2.6f Minimum R-Value of floor and subfloor wall insulation where the floor is over an enclosed subfloor space: climate zone 6

Part 13.2 Building fabric

Open Table 13.2.6f on NCC Online ↗
Subfloor wall height (mm)Reflective insulation facing down over the subfloor areaMinimum subfloor wall insulation R-ValueMinimum suspended floor insulation R-Value
≤600No0.02.0
≤600Yes0.01.5
>600 to ≤900No0.02.0
>600 to ≤900Yes0.01.5
>900 to ≤1200No0.02.0
>900 to ≤1200Yes0.01.5
>1200 to ≤1500No0.02.5
>1200 to ≤1500No0.52.0
>1200 to ≤1500Yes0.01.5
>1500 to ≤1800No0.02.5
>1500 to ≤1800Yes0.02.0
>1500 to ≤1800Yes0.51.5

Table Notes

A suspended floor includes a suspended timber-framed floor, suspended metal-framed floor and suspended concrete floor.

R-Values listed are for the labelled, declared R-Value of insulation.

Table for 13.2.6 Floors and subfloor walls

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.2.6f.

Defined terms used