Table · ABCB Housing Provisions 2022

Table 13.3.2ad Winter solar heat gain factors: climate zone 5 — concrete or masonry wall

Part 13.3 External glazing

Open Table 13.3.2ad on NCC Online ↗
Type of factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RW) for a bedroom and a room which is not a conditioned space0.400.30
Bedroom solar heat gain factor (BSW)1.000.60
Level factor (LW) for all floor levels above the lowest floor1.401.10
Frame factor (FW) for frames with a solar absorptance of ≤ 0.400.970.90
Frame factor (FW) for frames with a solar absorptance of > 0.40 to < 0.681.001.00
Frame factor (FW) for frames with a solar absorptance of ≥ 0.681.041.00
Floor factor (for tiled or vinyl covered floor) (HW)1.10Not applicable

Table Notes

This Table only applies to dwellings with both high mass external and internal walls, for example masonry cavity walls and masonry internal walls.

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2ad.