Table · ABCB Housing Provisions 2022

Table 13.3.2d Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 3

Part 13.3 External glazing

Open Table 13.3.2d on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.361.160.750.380.380.431.051.41
0.051.351.120.700.330.330.381.001.38
0.101.251.070.660.320.320.370.961.30
0.201.110.950.600.280.300.330.861.18
0.400.890.780.510.240.270.270.740.98
0.600.670.600.410.210.260.230.590.79
0.800.450.480.370.190.230.220.510.63
1.000.300.410.300.170.210.210.450.51
1.200.210.310.260.150.210.180.370.43
1.400.160.280.210.140.200.170.330.37
1.600.120.240.200.130.180.160.320.31
1.800.110.170.160.130.180.140.260.28
2.000.090.170.150.120.180.140.240.24

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2d.