Table · ABCB Housing Provisions 2022
Table 13.3.2e Orientation sector winter exposure factor (EW) — suspended floor: climate zone 3
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 1.92 | 1.29 | 0.97 | 0.82 | 0.75 | 1.07 | 1.24 | 1.69 |
| 0.05 | 1.90 | 1.24 | 0.90 | 0.72 | 0.66 | 0.94 | 1.18 | 1.65 |
| 0.10 | 1.76 | 1.18 | 0.86 | 0.69 | 0.63 | 0.91 | 1.13 | 1.56 |
| 0.20 | 1.57 | 1.05 | 0.77 | 0.62 | 0.60 | 0.81 | 1.01 | 1.41 |
| 0.40 | 1.25 | 0.86 | 0.66 | 0.51 | 0.54 | 0.68 | 0.87 | 1.17 |
| 0.60 | 0.94 | 0.66 | 0.53 | 0.46 | 0.51 | 0.59 | 0.70 | 0.94 |
| 0.80 | 0.63 | 0.53 | 0.47 | 0.41 | 0.45 | 0.55 | 0.60 | 0.76 |
| 1.00 | 0.42 | 0.45 | 0.39 | 0.36 | 0.42 | 0.52 | 0.53 | 0.61 |
| 1.20 | 0.29 | 0.35 | 0.34 | 0.33 | 0.42 | 0.46 | 0.44 | 0.52 |
| 1.40 | 0.23 | 0.31 | 0.28 | 0.31 | 0.39 | 0.42 | 0.39 | 0.44 |
| 1.60 | 0.17 | 0.27 | 0.26 | 0.28 | 0.36 | 0.39 | 0.38 | 0.37 |
| 1.80 | 0.15 | 0.19 | 0.21 | 0.28 | 0.36 | 0.36 | 0.31 | 0.34 |
| 2.00 | 0.13 | 0.19 | 0.20 | 0.26 | 0.36 | 0.36 | 0.29 | 0.29 |
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table for 13.3.2 External glazing — winter
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2e.