Table 13.3.2g Orientation sector winter exposure factor (EW) — suspended floor: climate zone 4

Part 13.3 External glazing

Open Table 13.3.2g on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.381.121.000.710.560.871.021.26
0.051.351.080.910.600.460.730.951.21
0.101.341.040.890.560.450.690.901.17
0.201.130.950.800.510.400.620.821.05
0.401.040.810.670.430.350.530.700.91
0.600.850.670.590.380.300.470.590.74
0.800.740.550.520.340.290.420.530.62
1.000.600.490.440.310.260.380.440.53
1.200.430.380.400.270.260.360.410.46
1.400.330.350.360.250.240.330.360.39
1.600.240.310.340.250.220.310.310.34
1.800.180.260.300.240.220.290.290.29
2.000.170.240.260.220.210.270.260.24

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter