Table · ABCB Housing Provisions 2022

Table 13.3.2h Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (lightweight wall)

Part 13.3 External glazing

Open Table 13.3.2h on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.611.551.000.490.440.471.021.58
0.051.561.490.910.410.370.400.941.51
0.101.561.430.860.390.360.380.901.47
0.201.301.270.770.350.320.340.801.32
0.401.191.050.640.300.280.290.661.10
0.600.970.870.520.260.250.250.560.90
0.800.780.710.460.240.230.230.500.73
1.000.640.550.360.210.220.200.430.63
1.200.430.480.330.200.200.190.350.50
1.400.320.360.270.190.190.180.340.43
1.600.220.320.250.180.170.160.280.36
1.800.180.260.210.160.170.160.240.32
2.000.140.200.200.150.170.140.230.24

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2h.