Table · ABCB Housing Provisions 2022

Table 13.3.2l Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 6

Part 13.3 External glazing

Open Table 13.3.2l on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.521.441.280.770.770.741.321.45
0.051.471.361.170.650.650.631.221.38
0.101.461.311.120.610.610.591.141.35
0.201.251.180.990.540.540.531.051.23
0.401.141.020.850.460.470.450.901.04
0.600.980.870.720.390.410.380.780.90
0.800.860.740.610.360.380.360.690.75
1.000.690.580.540.320.340.310.590.66
1.200.560.540.460.310.310.300.540.55
1.400.420.410.420.270.310.280.480.49
1.600.350.370.350.260.290.250.420.42
1.800.260.300.340.240.270.230.410.38
2.000.200.270.320.220.250230.360.30

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2l.