Table · ABCB Housing Provisions 2022
Table 13.3.2k Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (concrete or masonry wall)
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 1.71 | 1.24 | 1.00 | 0.63 | 0.44 | 0.94 | 1.19 | 1.54 |
| 0.05 | 1.66 | 1.19 | 0.91 | 0.53 | 0.37 | 0.80 | 1.09 | 1.47 |
| 0.10 | 1.66 | 1.14 | 0.86 | 0.50 | 0.36 | 0.77 | 1.05 | 1.43 |
| 0.20 | 1.39 | 1.01 | 0.77 | 0.45 | 0.32 | 0.68 | 0.94 | 1.28 |
| 0.40 | 1.27 | 0.84 | 0.64 | 0.39 | 0.28 | 0.58 | 0.77 | 1.07 |
| 0.60 | 1.03 | 0.69 | 0.52 | 0.34 | 0.25 | 0.51 | 0.66 | 0.87 |
| 0.80 | 0.83 | 0.57 | 0.46 | 0.31 | 0.23 | 0.46 | 0.59 | 0.71 |
| 1.00 | 0.68 | 0.43 | 0.36 | 0.27 | 0.22 | 0.41 | 0.50 | 0.61 |
| 1.20 | 0.46 | 0.38 | 0.33 | 0.26 | 0.20 | 0.39 | 0.41 | 0.49 |
| 1.40 | 0.34 | 0.28 | 0.27 | 0.24 | 0.19 | 0.36 | 0.39 | 0.42 |
| 1.60 | 0.24 | 0.25 | 0.25 | 0.23 | 0.17 | 0.31 | 0.32 | 0.35 |
| 1.80 | 0.19 | 0.21 | 0.21 | 0.21 | 0.17 | 0.31 | 0.28 | 0.31 |
| 2.00 | 0.15 | 0.16 | 0.20 | 0.19 | 0.17 | 0.29 | 0.27 | 0.23 |
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table for 13.3.2 External glazing — winter
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2k.