Table · ABCB Housing Provisions 2022

Table 13.3.2p Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 8

Part 13.3 External glazing

Open Table 13.3.2p on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.002.302.401.660.670.360.651.592.30
0.052.232.281.500.560.300.541.432.19
0.102.202.201.440.530.280.511.372.11
0.201.861.981.290.470.260.461.231.89
0.401.681.651.050.400.220.391.001.56
0.601.401.340.900.340.190.330.861.29
0.801.191.100.760.300.180.290.711.06
1.000.940.960.660.290.160.260.590.91
1.200.640.750.570.260.150.250.530.74
1.400.520.680.510.240.140.230.470.60
1.600.370.500.430.230.140.210.430.50
1.800.270.450.390.200.130.190.370.46
2.000.230.410.330.200.120.190.330.36

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2p.