Table · ABCB Housing Provisions 2022

Table 13.3.2q Orientation sector winter exposure factor (EW) — suspended floor — climate zone 8

Part 13.3 External glazing

Open Table 13.3.2q on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.391.271.220.800.590.901.051.28
0.051.351.211.100.660.490.740.951.22
0.101.331.171.050.630.460.710.911.17
0.201.121.050.950.560.420.630.821.05
0.401.020.880.770.470.350.530.660.87
0.600.850.710.660.410.310.460.570.72
0.800.720.580.560.360.290.400.470.59
1.000.570.510.480.340.260.360.390.51
1.200.390.400.420.300.250.340.350.41
1.400.320.360.380.290.230.320.310.33
1.600.220.270.320.270.220.290.290.28
1.800.170.240.290.240.210.270.250.25
2.000.140.220.240.240.200.270.220.20

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2q.