Table · ABCB Housing Provisions 2022

Table 13.3.3e Orientation sector summer exposure factor (ES) — suspended floor: climate zone 2

Part 13.3 External glazing

Open Table 13.3.3e on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.430.811.160.750.361.061.881.11
0.050.360.711.050.670.300.961.720.99
0.100.330.660.990.620.290.891.600.90
0.200.280.570.870.550.250.801.400.78
0.400.230.430.690.440.200.641.160.60
0.600.200.340.570.360.170.520.940.45
0.800.170.290.480.300.150.440.810.39
1.000.160.230.410.250.120.380.660.32
1.200.140.210.330.220.110.320.570.28
1.400.130.190.300.200.110.290.500.24
1.600.110.180.270.180.100.260.430.22
1.800.100.160.230.160.090.250.390.20
2.000.100.150.210.150.080.210.380.19

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3e.