Housing Provisions clause · ABCB Housing Provisions 2022

13.3.3 External glazing — summer

Part 13.3 External glazing

Open 13.3.3 on NCC Online ↗
Varied in NT. Check the variation for your state.

(1) In climate zones 1 to 7, the aggregate solar heat gain of the glazing in each storey of a building, including any mezzanine, must—

not exceed the allowance resulting from multiplying the floor area of each storey, measured within the enclosing walls, by the constant CSHGC obtained from Table 13.3.3a; and

be calculated in accordance with the following formula:

[formula] (2) In the formula at (1)(b)—

[formula] = the area of each glazing element; and

[formula] = the Total System SHGC for each glazing element not exceeding 0.7; and

[formula] = the summer exposure factor for each glazing element obtained from Table 13.3.3b, 13.3.3c, 13.3.3d, 13.3.3e, 13.3.3f, 13.3.3g, 13.3.3h, 13.3.3i, 13.3.3j, 13.3.3k, 13.3.3l, 13.3.3m, 13.3.3n, 13.3.3o, 13.3.3p or 13.3.3q; and

[formula] = the factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element located in a bedroom or room which is not a conditioned space; and

[formula] = the factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element located on a floor level above the lowest floor; and

[formula] = the frame factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element; and

[formula] = the floor factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element.

(3) For the purposes of this clause—

orientation sectors must be determined in accordance with Figure 13.3.2a; and

P/H must be measured in accordance with Figure 13.3.2b.

Table 13.3.3a Constant for solar heat gain coefficient (CSHGC): climate zones 1 to 7

Floor type

Ventilation opening area

Climate zone

1

2

3

4

5 (lightweight wall)

5 (concrete or brick wall)

6

7

Floor in direct contact with the ground

5%

0.0672

0.0595

0.0945

0.0604

0.0484

0.0657

0.0786

0.0762

10%

0.0718

0.0640

0.0985

0.0626

0.0538

0.0695

0.0817

0.0821

15%

0.0770

0.0682

0.1001

0.0641

0.0569

0.0714

0.0832

0.0871

20%

0.0827

0.0719

0.1007

0.0650

0.0587

0.0723

0.0840

0.0912

Suspended floor

5%

0.0431

0.0324

0.0768

0.0651

0.0334

0.0630

0.0963

0.0750

10%

0.0497

0.0404

0.0783

0.0697

0.0426

0.0683

0.0989

0.0778

15%

0.0541

0.0458

0.0792

0.0721

0.0477

0.0710

0.1001

0.0789

20%

0.0570

0.0494

0.0796

0.0734

0.0505

0.0723

0.1007

0.0793

Table Notes

The ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.

No window may have a design ventilation opening greater than 90% because the window frame will always obstruct some of the area of the opening.

Where the ventilation opening area is more than 20%, the CSHGC value corresponding to 20% ventilation opening area is to be used.

Where the floor construction of a storey, including any mezzanine, is partly in direct contact with the ground and partly suspended, the constant is to be—

interpolated between the constants in proportion to the floor area of each floor type; or

the constant for a suspended floor.

If the ventilation opening area is between the values shown in this Table, the constant may be interpolated.

Table 13.3.3b Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 1

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.35

1.64

1.69

1.62

1.13

1.65

1.72

1.66

0.05

1.14

1.45

1.56

1.47

0.98

1.52

1.60

1.46

0.10

1.07

1.33

1.45

1.40

0.88

1.42

1.50

1.35

0.20

0.96

1.15

1.32

1.23

0.72

1.22

1.30

1.17

0.40

0.78

0.88

1.03

0.90

0.55

0.98

1.08

0.92

0.60

0.65

0.72

0.86

0.77

0.44

0.78

0.86

0.74

0.80

0.57

0.61

0.69

0.61

0.39

0.68

0.75

0.62

1.00

0.49

0.51

0.59

0.54

0.33

0.56

0.62

0.55

1.20

0.47

0.45

0.48

0.43

0.29

0.51

0.55

0.51

1.40

0.44

0.41

0.42

0.39

0.29

0.42

0.48

0.43

1.60

0.39

0.35

0.37

0.34

0.23

0.38

0.44

0.41

1.80

0.34

0.35

0.35

0.29

0.22

0.36

0.39

0.35

2.00

0.31

0.33

0.30

0.27

0.21

0.31

0.36

0.33

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table 13.3.3c Orientation sector summer exposure factor (ES) — suspended floor: climate zone 1

P/H

North

North east

East

South East

South

South west

West

North west

0.00

0.61

0.96

1.43

1.19

0.70

1.15

1.32

0.92

0.05

0.51

0.84

1.32

1.08

0.61

1.06

1.23

0.81

0.10

0.48

0.78

1.23

1.03

0.55

0.99

1.15

0.75

0.20

0.43

0.67

1.12

0.90

0.45

0.85

1.00

0.65

0.40

0.35

0.51

0.88

0.66

0.34

0.68

0.83

0.51

0.60

0.29

0.42

0.73

0.57

0.28

0.54

0.66

0.41

0.80

0.26

0.35

0.59

0.45

0.24

0.47

0.58

0.35

1.00

0.22

0.30

0.50

0.39

0.20

0.39

0.48

0.30

1.20

0.21

0.26

0.41

0.32

0.18

0.35

0.42

0.28

1.40

0.20

0.24

0.36

0.29

0.18

0.29

0.37

0.24

1.60

0.18

0.21

0.31

0.25

0.15

0.26

0.34

0.23

1.80

0.15

0.21

0.30

0.21

0.14

0.25

0.30

0.20

2.00

0.14

0.19

0.26

0.20

0.13

0.22

0.28

0.18

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table 13.3.3d Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 2

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.59

1.08

1.50

0.93

0.40

1.05

1.78

1.19

0.05

0.49

0.94

1.35

0.82

0.33

0.95

1.64

1.06

0.10

0.45

0.87

1.28

0.77

0.31

0.88

1.52

0.97

0.20

0.39

0.76

1.13

0.68

0.28

0.79

1.33

0.84

0.40

0.32

0.57

0.90

0.54

0.22

0.63

1.10

0.65

0.60

0.27

0.45

0.74

0.44

0.18

0.52

0.89

0.48

0.80

0.24

0.38

0.62

0.36

0.16

0.43

0.77

0.42

1.00

0.21

0.31

0.53

0.31

0.13

0.38

0.63

0.34

1.20

0.19

0.28

0.43

0.27

0.12

0.32

0.55

0.30

1.40

0.17

0.25

0.39

0.25

0.12

0.28

0.48

0.26

1.60

0.16

0.24

0.34

0.22

0.10

0.25

0.41

0.24

1.80

0.14

0.21

0.30

0.20

0.09

0.24

0.37

0.22

2.00

0.14

0.19

0.27

0.19

0.09

0.21

0.36

0.20

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table 13.3.3e Orientation sector summer exposure factor (ES) — suspended floor: climate zone 2

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.43

0.81

1.16

0.75

0.36

1.06

1.88

1.11

0.05

0.36

0.71

1.05

0.67

0.30

0.96

1.72

0.99

0.10

0.33

0.66

0.99

0.62

0.29

0.89

1.60

0.90

0.20

0.28

0.57

0.87

0.55

0.25

0.80

1.40

0.78

0.40

0.23

0.43

0.69

0.44

0.20

0.64

1.16

0.60

0.60

0.20

0.34

0.57

0.36

0.17

0.52

0.94

0.45

0.80

0.17

0.29

0.48

0.30

0.15

0.44

0.81

0.39

1.00

0.16

0.23

0.41

0.25

0.12

0.38

0.66

0.32

1.20

0.14

0.21

0.33

0.22

0.11

0.32

0.57

0.28

1.40

0.13

0.19

0.30

0.20

0.11

0.29

0.50

0.24

1.60

0.11

0.18

0.27

0.18

0.10

0.26

0.43

0.22

1.80

0.10

0.16

0.23

0.16

0.09

0.25

0.39

0.20

2.00

0.10

0.15

0.21

0.15

0.08

0.21

0.38

0.19

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table 13.3.3f Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 3

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.95

1.51

1.70

1.53

0.92

1.45

1.50

1.41

0.05

0.80

1.36

1.58

1.40

0.80

1.31

1.39

1.26

0.10

0.75

1.23

1.50

1.33

0.76

1.24

1.31

1.16

0.20

0.65

1.06

1.32

1.17

0.64

1.09

1.17

1.02

0.40

0.54

0.81

1.06

0.92

0.53

0.90

0.92

0.78

0.60

0.48

0.62

0.89

0.75

0.43

0.71

0.78

0.62

0.80

0.41

0.51

0.71

0.61

0.38

0.63

0.66

0.49

1.00

0.34

0.42

0.60

0.52

0.34

0.54

0.58

0.41

1.20

0.32

0.38

0.50

0.44

0.29

0.46

0.47

0.36

1.40

0.29

0.32

0.42

0.40

0.28

0.40

0.45

0.32

1.60

0.29

0.29

0.40

0.35

0.22

0.39

0.39

0.29

1.80

0.26

0.28

0.36

0.31

0.22

0.35

0.36

0.27

2.00

0.26

0.26

0.30

0.31

0.21

0.30

0.30

0.24

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table 13.3.3g Orientation sector summer exposure factor (ES) — suspended floor: climate zone 3

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.78

1.30

1.56

1.36

0.79

1.16

1.09

1.11

0.05

0.66

1.18

1.45

1.24

0.68

1.05

1.01

0.99

0.10

0.62

1.06

1.38

1.17

0.65

0.99

0.95

0.91

0.20

0.53

0.91

1.21

1.04

0.55

0.87

0.85

0.80

0.40

0.45

0.70

0.97

0.82

0.46

0.72

0.67

0.62

0.60

0.39

0.54

0.81

0.67

0.37

0.57

0.57

0.48

0.80

0.34

0.44

0.65

0.54

0.32

0.50

0.48

0.39

1.00

0.28

0.36

0.55

0.46

0.29

0.43

0.42

0.32

1.20

0.27

0.33

0.46

0.39

0

Tables

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 13.3.3.

State and territory variations all clauses side by side →

Defined terms used