Table 13.3.3k Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (concrete or masonry wall)

Part 13.3 External glazing

Open Table 13.3.3k on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.981.141.070.600.240.781.501.36
0.050.831.010.960.530.200.691.371.22
0.100.760.920.910.490.190.651.281.10
0.200.610.800.800.440.170.571.140.98
0.400.470.610.640.360.130.470.930.73
0.600.420.480.520.290.120.380.750.56
0.800.360.390.450.250.100.320.600.47
1.000.310.330.380.210.090.280.530.36
1.200.290.270.320.190.080.250.460.32
1.400.250.240.290.170.070.220.390.28
1.600.240.230.260.140.060.200.350.25
1.800.220.210.230.130.060.170.310.24
2.000.200.180.220.130.060.160.290.22

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3k.