Table · ABCB Housing Provisions 2022

Table 13.3.3q Orientation sector summer exposure factor (ES) — suspended floor: climate zone 7

Part 13.3 External glazing

Open Table 13.3.3q on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.151.170.970.750.510.771.071.24
0.051.001.050.880.660.430.690.981.12
0.100.910.970.830.640.410.650.931.03
0.200.740.850.740.560.360.580.820.90
0.400.480.650.610.460.300.470.670.67
0.600.380.510.520.400.260.400.570.54
0.800.340.400.430.350.220.350.480.42
1.000.300.330.380.300.200.300.400.34
1.200.260.280.330.270.180.260.340.28
1.400.230.230.290.240.170.240.300.25
1.600.220.210.260.220.160.220.280.22
1.800.200.200.220.190.140.200.240.20
2.000.190.190.220.180.140.180.230.19

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3q.