Table 4.2.14c Reinforcement for stiffened raft footings for Class M sites

Part 4.2 Footings, slabs and associated elements

Open Table 4.2.14c on NCC Online ↗
Type of constructionDepth (D) (mm)Bottom reinf.Max. spacing c/l to c/lSlab mesh
Clad frame3003-L11TM6.0Note 2SL72
Articulated masonry veneer4003-L11TM6.0Note 2SL72
Masonry veneer4003-L11TM5.0Note 2SL72
Articulated full masonry5003-L12TM4.0SL82
Full masonry8503-N164.0SL92

Table Notes

Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).

A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.

Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.

Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.

Alternative reinforcement sizes must comply with AS 2870.

Internal beam details and spacings must comply with Figure 4.2.14b.

Table for 4.2.14 Stiffened rafts Class A, S and M sites

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 4.2.14c.