Table · ABCB Housing Provisions 2022

Table 6.3.6c Required column section — columns supporting tiled floor and tiled roof load — roof load area = 18 m2

Part 6.3 Structural steel members

Open Table 6.3.6c on NCC Online ↗
Column sectionEffective height (mm)Floor load area (m2)
41016
CHS 250240088.9 x 5 CHS114.3 x 5.4 CHS139.7 x 5 CHS
CHS 250270088.9 x 5 CHS114.3 x 5.4 CHS139.7 x 5 CHS
CHS 250300088.9 x 5 CHS114.3 x 5.4 CHS139.7 x 5 CHS
CHS 250330088.9 x 5.9 CHS114.3 x 5.4 CHS139.7 x 5 CHS
CHS 250360088.9 x 5.9 CHS114.3 x 5.4 CHS139.7 x 5 CHS
CHS 3502400101.6 x 2.6 CHS114.3 x 3.6 CHS139.7 x 3.5 CHS
CHS 3502700101.6 x 2.6 CHS114.3 x 3.6 CHS139.7 x 3.5 CHS
CHS 3503000101.6 x 3.2 CHS114.3 x 3.6 CHS139.7 x 3.5 CHS
CHS 3503300101.6 x 3.2 CHS114.3 x 3.6 CHS139.7 x 3.5 CHS
CHS 3503600101.6 x 3.2 CHS114.3 x 3.6 CHS139.7 x 3.5 CHS
SHS 350240089 x 89 x 3.5 SHS100 x 100 x 4 SHS100 x 100 x 4 SHS
SHS 350270089 x 89 x 3.5 SHS100 x 100 x 4 SHS100 x 100 x 4 SHS
SHS 350300089 x 89 x 3.5 SHS100 x 100 x 4 SHS100 x 100 x 5 SHS
SHS 3503300100 x 100 x 3 SHS100 x 100 x 4 SHS100 x 100 x 5 SHS
SHS 3503600100 x 100 x 3 SHS100 x 100 x 4 SHS100 x 100 x 5 SHS
SHS 450240089 x 89 x 3.5 SHS100 x 100 x 3 SHS100 x 100 x 4 SHS
SHS 450270089 x 89 x 3.5 SHS100 x 100 x 3 SHS100 x 100 x 4 SHS
SHS 450300089 x 89 x 3.5 SHS100 x 100 x 3 SHS100 x 100 x 4 SHS
SHS 450330089 x 89 x 3.5 SHS100 x 100 x 3 SHS100 x 100 x 4 SHS
SHS 450360089 x 89 x 3.5 SHS100 x 100 x 3 SHS100 x 100 x 4 SHS

Table Notes

Load accounted for includes 0.98 kPa permanent floor, 1.16 kN/m permanent wall, 0.85 kPa permanent roof, permanent member self-weight, 1.5 kPa or 1.1 kN imposed floor and 0.25 kPa imposed roof.

Load combinations included are 1.35G and 1.2G + 1.5Q for ULS.

Columns are assumed to be simply-supported at both ends with an effective length factor of 1.

A maximum load eccentricity of 100 mm has been accounted for in the columns.

A roof load area of “0” must be used for columns not supporting roof loads.

The length of wall load allowed for is equal to the square root of the floor area.

Table for 6.3.6 Columns

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 6.3.6c.

Defined terms used