Floor area
For the purposes of—
Volume One—
in relation to a building — the total area of all storeys; and
in relation to a storey — the area of all floors of that storey measured over the enclosing walls, and includes—
the area of a mezzanine within the storey, measured within the finished surfaces of any external walls; and
the area occupied by any internal wall or partitions, any cupboard, or other built-in furniture, fixture or fitting; and
if there is no enclosing wall, an area which has a use that contributes to the fire load or impacts on the safety, health or amenity of the occupants in relation to the provisions of the BCA; and
in relation to a room — the area of the room measured within the internal finished surfaces of the walls, and includes the area occupied by any cupboard or other built-in furniture, fixture or fitting; and
in relation to a fire compartment — the total area of all floors within the fire compartment measured within the finished internal surfaces of the bounding construction, and if there is no bounding construction, includes an area which has a use which contributes to the fire load; and
in relation to an atrium — the total area of all floors within the atrium measured within the finished surfaces of the bounding construction and if no bounding construction, within the external walls.
Volume Two and the ABCB Housing Provisions, in relation to a room, the area of the room measured within the finished surfaces of the walls, and includes the area occupied by any cupboard or other built-in furniture, fixture or fitting (see Figure 4).
Figure 4 Identification of floor area of a room
Used in
- 10.3.1 Height of rooms and other spaces
- 10.5.1 Natural light
- 10.5.2 Artificial lighting
- 10.6.2 Ventilation requirements
- Table 13.2.4 Roof lights – Total System SHGC
- 13.2.4 Roof lights
- Table 13.3.3a Constant for solar heat gain coefficient (CSHGC): climate zones 1 to 7
- 13.3.3 External glazing — summer
- Table 13.6.2a Floor area adjustment factor
- 13.6.2 Net equivalent energy usage
- Table 4.2.13a Stumps supporting single storey timber floor and metal roof
- Table 4.2.13b Stumps supporting single storey tiled floor and tiled roof
- Table 4.2.13c Stumps supporting double storey timber floor and metal roof
- Table 4.2.13d Maximum stump height (mm): stump supporting single storey timber floor and metal roof
- Table 4.2.13e Maximum stump height: stump supporting single storey tiled floor and tiled roof
- Table 4.2.13f Maximum stump height: stump supporting double storey timber floor and metal roof
- Table 4.2.13g Minimum dimensions of circular and square pad footings for clad frame, Class A and S sites
- 4.2.13 Stump footing details
- Table 4.2.20a Localised thickening under concentrated load — tiled floor and tiled roof — roof load area = 0 m2
- Table 4.2.20b Localised thickening under concentrated load — tiled floor and tiled roof — roof load area = maximum 9 m2