Table 7.5.3a Fixing requirements—Minimum 7.5 mm thick fibre-cement wall cladding boards
Part 7.5 Timber and composite wall cladding
| Wind class | Maximum stud spacing (mm) | Minimum nominal stud fixings |
|---|---|---|
| N1 - N3 | 600 | Timber: 2.8 GC |
Steel: (8-18) S
Table Notes
GC = galvanised fibre-cement nail.
S = self embedding or wafer head screw.
Fasteners must penetrate not less than 30 mm into timber frames and not less than two full screw threads through steel frames.
Steel framing members must have a base metal thickness (BMT) not less than that required for a roof batten in NASH standard.
Wall cladding may be fixed through timber or metal battens attached to the wall frame in accordance with AS 1684.2, AS 1684.3, AS 1684.4 or NASH standard as appropriate (see fixing requirements for roof battens) so long as the minimum penetration into the wall frame is achieved.
Table for 7.5.3 Wall cladding boards
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 7.5.3a.