ABCB Housing Provisions 2022
Part 7.5 Timber and composite wall cladding
15 clauses · Open on NCC Online ↗
- 7.5.1 ApplicationCompliance with Part 7.5 for wall cladding is achieved if— it is installed in accordance with— 7.5.2 for timber cladding, including weatherboards…
- Table 7.5.2 Fixing requirements—Splayed and profiled timber weatherboardsWind class | Maximum stud spacing (mm) | Minimum nominal stud fixings N1 - N3 | 600 | Timber: 2.8 G or (8-18) S Steel: (8-18) S Table Notes G =…
- 7.5.2 Timber wall claddingTimber wall cladding must be installed in accordance with (2), (3), (4) and (5). (2) Splayed timber weatherboards must be fixed in accordance with…
- Table 7.5.3a Fixing requirements—Minimum 7.5 mm thick fibre-cement wall cladding boardsWind class | Maximum stud spacing (mm) | Minimum nominal stud fixings N1 - N3 | 600 | Timber: 2.8 GC Steel: (8-18) S Table Notes GC = galvanised…
- Table 7.5.3b Fixing requirements—Minimum 9.5 mm thick hardboard wall cladding boardsWind class | Maximum stud spacing (mm) | Minimum nominal stud fixings N1 - N3 | 600 | Timber: 2.8 GC Steel: (8-18) S Table Notes GC = galvanised…
- 7.5.3 Wall cladding boardsWall cladding boards must— for 7.5 mm (minimum) thick fibre-cement — comply with AS/NZS 2908.2 or ISO 8336; and for 9.5 mm (minimum) thick hardboard…
- Table 7.5.4a Stud and fixing spacings for 6 mm fibre-cement sheet wall claddingWind class | Maximum stud spacing (mm) | Maximum nail spacing within 1.2 m of the external corners of the building (mm) Note 1 | Maximum nail…
- Table 7.5.4b Stud and fixing spacings for 9.5 mm thick hardboard sheet wall claddingWind class | Maximum stud spacing (mm) | Maximum nail spacing within 1.2 m of the external corners of the building (mm) Note 1 | Maximum nail…
- Table 7.5.4c Stud and fixing spacings for plywood wall cladding equal to or greater than 6.5 mm thickWind class | Maximum stud spacing (mm) | Maximum nail spacing within 1.2 m of the external corners of the building (mm) Note 1 | Maximum nail…
- 7.5.4 Sheet wall claddingFibre-cement sheet wall cladding must— comply with AS/NZS 2908.2 or ISO 8336; and be fixed in accordance with Table 7.5.4a. (2) Hardboard sheet wall…
- Table 7.5.5 Trimmer and fastener spacings for 4.5 mm and 6 mm fibre-cement eaves and soffit liningsMaximum eaves width | Wind class | Maximum trimmer spacings (mm) | Maximum fastener spacings (mm) Within 1200 mm of the external corners of the…
- 7.5.5 Eaves and soffit liningsWhere provided, external fibre-cement sheets and linings used as eaves and soffit linings must— comply with AS/NZS 2908.2 or ISO 8336; and be fixed…
- 7.5.6 Flashings to wall openingsOpenings in external wall cladding exposed to the weather must be flashed with materials complying with AS/NZS 2904 and in accordance with the…
- 7.5.7 Clearance between cladding and groundThe minimum clearance from the bottom of the wall cladding to the adjoining finished ground level must be— 100 mm in low rainfall intensity areas or…
- 7.5.8 Parapet cappingsWhere a wall cladding is used to form a parapet wall, the cladding must be attached to a supporting frame and have a capping installed that complies…