Deemed-to-Satisfy Provision · NCC 2022 Volume One

D4D9 Tactile indicators

Part D4 Access for people with a disability · NCC 2019: D3.8

Open D4D9 on NCC Online ↗

(1) For a building required to be accessible, tactile ground surface indicators must be provided to warn people who are blind or have a vision impairment that they are approaching—

a stairway, other than a fire-isolated stairway; and

an escalator; and

a passenger conveyor or moving walk; and

a ramp other than a fire-isolated ramp, step ramp, kerb ramp or swimming pool ramp; and

in the absence of a suitable barrier—

an overhead obstruction less than 2 m above floor level, other than a doorway; and

an accessway meeting a vehicular way adjacent to any pedestrian entrance to a building, excluding a pedestrian entrance serving an area referred to in D4D5, if there is no kerb or kerb ramp at that point,

except for areas exempted by D4D5.

(2) Tactile ground surface indicators required by (1) must comply with sections 1 and 2 of AS/NZS 1428.4.1.

(3) A hostel for the aged, nursing home for the aged, a residential aged care building, Class 3 accommodation for the aged, Class 9a health-care building or a Class 9c aged care building need not comply with (1)(a) and (d) if handrails incorporating a raised dome button in accordance with AS/NZS 1428.4.1 are provided to warn people who are blind or have a vision impairment that they are approaching a stairway or ramp.

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One D4D9.
Can't meet D4D9? A Performance Solution must meet the Performance Requirements it satisfies: D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P8, D1P9. Start a Performance Solution →