Deemed-to-Satisfy Provision · NCC 2022 Volume One

F4D6 Accessible unisex sanitary compartments

Part F4 Sanitary and other facilities · NCC 2019: Table F2.4a

Open F4D6 on NCC Online ↗
Varied in SA. Check the variation for your state.

(1) Where required by F4D5(a), the minimum number of accessible unisex sanitary compartments for each class of building is as follows:

For a Class 1b building—

not less than 1; and

where private accessible unisex sanitary compartments are provided for every accessible bedroom, common accessible unisex sanitary compartments need not be provided.

For a Class 2 building, where sanitary compartments are provided in common areas, not less than 1.

For Class 3 and Class 9c buildings—

in every accessible sole-occupancy unit provided with sanitary compartments within the accessible sole-occupancy unit, not less than 1; and

at each bank of sanitary compartments containing male and female sanitary compartments provided in common areas, not less than 1.

For Class 5, 6, 7, 8 or 9 buildings, where F4D4 requires closet pans—

1 on every storey containing sanitary compartments; and

where a storey has more than 1 bank of sanitary compartments containing male and female sanitary compartments, at not less than 50% of those banks.

For a Class 10a building, at each bank of sanitary compartments containing male and female sanitary compartments, not less than 1.

(2) The requirements of (1)(d) do not apply within a ward area of a Class 9a health-care building.

(3) The requirements of (1)(e) do not apply to—

a Class 10a appurtenant to another class of building; or

a sanitary compartment dedicated to a single caravan/camping site.

Changed in NCC 2025. See NCC 2025 Volume One F4D6, or show what changed.

(1) Where required by F4D5(a), the minimum number of accessible … less than 1; and at each bank of sanitary compartments containing male and female sanitary compartments provided in common areas, areas containing 2 or more sanitary compartments, not less than 1. For Class 5, 6, 7, 8 … Class 10a building, at each bank of sanitary compartments containing male and female 2 or more sanitary compartments, not less than 1. (2) The requirements of … or a sanitary compartment dedicated to a single caravan/camping site.

Removed words are struck through; added words are highlighted. Comparison of the text only.

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used