NSW D3D14 Goings and risers
Part D3 Construction of exits · varies D3D14 Goings and risers
Delete subclause D3D14(1) and insert NSW D3D14(1) as follows:
(1) A stairway must have—
not more than 18 and not less than 2 risers in each flight; and
going (G), riser (R) and quantity (2R + G) in accordance with Table D3D14, except as permitted by (2) and (3); and
constant goings and risers throughout each flight, except as permitted by (2) and (3), and the dimensions of goings (G) and risers (R) in accordance with (1)(b) are considered constant if the variation between—
adjacent risers, or between adjacent goings, is no greater than 5 mm; and
the largest and smallest riser within a flight, or the largest and smallest going within a flight, does not exceed 10 mm; and
risers which do not have any openings that would allow a 125 mm sphere to pass through between the treads; and
treads which have—
a surface with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; or
a nosing strip with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; and
treads of solid construction (not mesh or other perforated material) if the stairway is more than 10 m high or connects more than 3 storeys; and
in a Class 9b building, not more than 36 risers in consecutive flights without a change in direction of at least 30°; and
in the case of a required stairway, no winders in lieu of a landing; and
conspicuous edges to the treads of steps in a Class 9b building used as an entertainment venue; and
in a Class 9b building used as an entertainment venue, not more than one helical stairway serving as a required exit and that stairway must—
have a width of not less than 1500 mm; and
be of constant radius; and
be constructed so that each tread, when measured 500 mm in from its narrow end, has a width of at least 280 mm; and
in a Class 9b building used as an entertainment venue, in a curved stairway serving as a required exit — an internal radius of not less than twice the width of the stair.