Delete subclause D3D18(1) and insert NSW D3D18(1) as follows:

(1) The height of a barrier required by D3D17 must be not less than the following:

For stairways or ramps with a gradient of 1:20 or steeper — 865 mm.

For landings to a stair or ramp where the barrier is provided along the inside edge of the landing and does not exceed 500 mm in length — 865 mm.

In front of fixed seating on a mezzanine or balcony within an auditorium in a Class 9b building—

1 m; or

700 mm where the horizontal projection extends not less than 1 m outwards from the top of the barrier; or

in a Class 9b building used as an entertainment venue, the height prescribed for guardrails in NSW I4D41 or NSW I5D9.

In a Class 9b building used as an entertainment venue, for stairways and ramps and the floor of any access path, balcony, landing or the like—

1 m when provided inside the building; and

1200 mm when provided externally to the building.

For all other locations — 1 m.

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One NSW D3D18.