D3D18 Height of barriers
Part D3 Construction of exits · NCC 2019: Table D2.16a
(1) The height of a barrier required by D3D17 must be not less than the following:
For stairways or ramps with a gradient of 1:20 or steeper — 865 mm.
For landings to a stair or ramp where the barrier is provided along the inside edge of the landing and does not exceed 500 mm in length — 865 mm.
In front of fixed seating on a mezzanine or balcony within an auditorium in a Class 9b building, where the horizontal projection extends not less than 1 m outwards from the top of the barrier — 700 mm.
For all other locations — 1 m.
(2) For a barrier provided under (1) —
barrier heights are measured vertically from the surface beneath, except that for stairways the height must be measured above the nosing line of the stair treads; and
a transition zone may be incorporated where the barrier height changes from 865 mm on a stair flight or ramp to 1 m at a landing or floor.