New South Wales variation · NCC 2022 Volume One

NSW D3D24 Doorways and doors

Part D3 Construction of exits · varies D3D24 Doorways and doors

Open on NCC Online ↗

Delete subclause D3D24(2) and insert NSW D3D24(2) as follows:

(2) A doorway serving as a required exit or forming part of a required exit, or a doorway in a patient care area of a Class 9a health-care building—

must not be fitted with a revolving door; and

must not be fitted with a roller shutter or tilt-up door unless—

it serves a Class 6, 7 or 8 building or part with a floor area not more than 200 m2; and

the doorway is the only required exit from the building or part; and

it is held in the open position while the building or part is lawfully occupied; and

must not be fitted with a sliding door unless—

it leads directly to a road or open space; and

the door is able to be opened manually under a force of not more than 110 N; and

if fitted with a door which is power-operated—

it must be able to be opened manually under a force of not more than 110 N if there is a malfunction or failure of the power source; and

if it leads directly to a road or open space it must open automatically if there is a power failure to the door or on the activation of a fire or smoke alarm anywhere in the fire compartment served by the door; and

in a Class 9b building used as an entertainment venue—

must not be fitted with a collapsible gate, accordion door, turnstile or rigid barrier; and

if fitted with a door, must be—

a swing door which opens in the direction of egress; and

doors hung in two folds where the unobstructed width of the doorway is more than 1 m; and

a doorway or opening within sight of the audience but not intended for egress must have a notice displayed clearly indicating its purpose and such a notice must not be internally illuminated; and

notwithstanding (2)(c), a sliding door may be fitted where—

it leads directly to a road or open space and forms a main entrance; and

it is capable of swinging in the direction of egress when pressure is applied to the inside face of the door; and

the door is provided with signage that clearly indicates to persons seeking egress, the potential for swinging the door open in an emergency.

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One NSW D3D24.

The national clause