NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres

Open on NCC Online ↗

A stage which is more than 50 m2 in area, and all areas below such a stage, must (with the exception of the proscenium opening) be separated from the backstage and the remainder of the building by construction having an FRL of not less than 60/60/60.