New South Wales variation · NCC 2022 Volume One

NSW J5D5 Windows and doors

Part J5 Building sealing · varies J5D5 Windows and doors

Open on NCC Online ↗

Delete clause J5D5 and insert NSW J5D5 as follows:

(1) A door, openable window or the like must be sealed—

when forming part of the envelope; or

in climate zones 4, 5, 6, 7 or 8.

(2) The requirements of (1) do not apply to—

a window complying with AS 2047; or

a fire door or smoke door; or

a roller shutter door, roller shutter grille or other security door or device installed only for out-of-hours security.

(3) A seal to restrict air infiltration—

for the bottom edge of a door, must be a draft protection device; and

for the other edges of a door or the edges of an openable window or other such opening, may be a foam or rubber compression strip, fibrous seal or the like.

(4) An entrance to a building, if leading to a conditioned space must have an airlock, self-closing door, rapid roller door, revolving door or the like, other than—

where the conditioned space has a floor area of not more than 50 m2; or

where a café, restaurant, open front shop or the like has—

a 3 m deep un-conditioned zone between the main entrance, including an open front, and the conditioned space; and

at all other entrances to the café, restaurant, open front shop or the like, self-closing doors.

(5) A loading dock entrance, if leading to a conditioned space, must be fitted with a rapid roller door or the like.

Applications

NSW J5D5(5) does not apply to a Class 2 building or a Class 4 part of a building.

Not in NCC 2025. No NSW J5D5 in NCC 2025 Volume One.

The national clause