NCC 2022 Volume One
Part F3 Roof and wall cladding
11 clauses · Open on NCC Online ↗
- F3O1 ObjectiveThe Objective of this Part is to— safeguard occupants from illness or injury and protect buildings from damage caused by— ingress of water from…
- F3F1 Roof and wall claddingA building is to be constructed to prevent penetration of water from the outside.
- F3P1 WeatherproofingA roof and external wall (including openings around windows and doors) must prevent the penetration of water that could cause— unhealthy or…
- Table F3V1a Risk factors and scoresRisk factor | Category | Risk severity | Score Wind region | Region A0-5 (AS/NZS 1170.2) | Low to medium | 0 Region B1-2 (AS/NZS 1170.2) Region C…
- Table F3V1b Cyclic pressureStage number | Serviceability wind pressure (%) Min | Max 1 | 15 | 30 2 | 20 | 40 3 | 30 | 60
- F3V1 WeatherproofingCompliance with F3P1 for weatherproofing of an external wall is verified when— a prototype passes the procedure described in (2); and the external…
- F3D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirement F3P1 is satisfied by complying with F3D2 to F3D5. (2) Where a Performance…
- F3D2 Roof coveringsA roof must be covered with— roof tiles complying with AS 2049, fixed in accordance with AS 2050; or metal sheet roofing complying with AS 1562.1;…
- F3D3 SarkingSarking-type material used for weatherproofing of roofs and walls must comply with AS 4200.1 and AS 4200.2.
- F3D4 Glazed assembliesSubject to (2) and (3), the following glazed assemblies in an external wall, must comply with AS 2047 requirements for resistance to water…
- F3D5 Wall claddingExternal wall cladding must comply with one or a combination of the following: Masonry, including masonry veneer, unreinforced and reinforced…