Delete clause E4D5 and insert SA E4D5 as follows:
An exit sign must be clearly visible to persons approaching the exit, and must be installed on, above or adjacent to each—
door providing direct egress from a storey to—
an enclosed stairway, passageway or ramp serving as a required exit; and
an external stairway, passageway or ramp serving as a required exit; and
an external access balcony leading to a required exit; and
door from an enclosed stairway, passageway or ramp at every level of discharge to a road or open space; and
horizontal exit; and
door serving as, or forming part of, a required exit in a storey required to be provided with emergency lighting in accordance with E4D2; and
requiredexit in a farm building.