South Australia variation · NCC 2022 Volume One

SA E4D5 Exit signs

Part E4 Visibility in an emergency, exit signs and warning systems · varies E4D5 Exit signs

Open on NCC Online ↗

Delete clause E4D5 and insert SA E4D5 as follows:

An exit sign must be clearly visible to persons approaching the exit, and must be installed on, above or adjacent to each—

door providing direct egress from a storey to—

an enclosed stairway, passageway or ramp serving as a required exit; and

an external stairway, passageway or ramp serving as a required exit; and

an external access balcony leading to a required exit; and

door from an enclosed stairway, passageway or ramp at every level of discharge to a road or open space; and

horizontal exit; and

door serving as, or forming part of, a required exit in a storey required to be provided with emergency lighting in accordance with E4D2; and

requiredexit in a farm building.

Not in NCC 2025. No SA E4D5 in NCC 2025 Volume One.

The national clause