Table J3D11e Orientation sector winter exposure factor (EW): climate zone 5

Part J3 Elemental provisions for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Open Table J3D11e on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.611.341.080.870.670.760.851.23
0.051.561.290.980.740.560.640.781.17
0.101.561.230.920.690.540.620.751.14
0.201.301.100.830.630.490.540.671.03
0.401.190.910.690.540.410.470.550.86
0.600.970.750.560.470.380.410.470.70
0.800.780.620.490.420.340.370.420.57
1.000.640.470.390.380.320.330.360.49
1.200.430.420.350.360.310.310.290.39
1.400.320.310.290.340.290.290.280.33
1.600.220.270.270.310.250.250.230.28
1.800.180.230.220.290.250.250.200.25
2.000.140.170.210.270.250.230.190.19

Table for J3D11 External winter glazing of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table J3D11e.